Skip to content

SOLUTIONS FOR FACTORIES · FDI ENTERPRISES · INDUSTRIAL PARKS

Factory Energy Monitoring & Machine Retrofit Data Acquisition

Extract telemetry from legacy machines. Sub-meter electrical power per machine and monitor Run/Stop/Idle uptime without altering PLC logic or interrupting production lines.

Not every factory can overhaul its PLC infrastructure or invest hundreds of thousands of dollars in new machinery. DeviceLab offers a non-invasive Retrofit approach: add external clip-on sensors, Split-core CTs, and industrial IoT edge gateways to meter power per shift, monitor Run/Stop/Idle cycles, and quantify piece count. Start with a risk-free 1–3 machine PoC in 2–4 weeks to verify figures before scaling plant-wide.

Factory power distribution panel, energy meter and IoT data acquisition gateway
  • ✓ Zero PLC Touch: External clip-on sensors & split-core CTs
  • ✓ 1–3 Machine PoC: 2–4 week pilot before major investment
  • ✓ 100% IP & Data Ownership: Complete handover of data, schematics & configs

Solution Direct Answer

DeviceLab legacy machine data acquisition delivers a complete non-invasive IIoT Retrofit architecture: external clip-on sensors and 2.5kV optically isolated industrial gateways meter electrical energy (kWh, kW, Peak), track Run/Stop/Idle status, count output, and calculate OEE per shift. Implementation adheres to our 3 ZERO commitments: zero production downtime, zero PLC program modification, zero IT office network intrusion. Clients start with a 1–3 machine PoC in 2–4 weeks to prove ROI.

Core Values Delivered to Manufacturing Plants

  • Zero PLC modification required: Collect telemetry via external sensors, auxiliary dry contacts, and Split-core CTs, keeping original machine control logic 100% intact.
  • Start with a 1–3 machine PoC: Pilot for 2–4 weeks to uncover idle power waste and validate ROI before committing to plant-wide rollout.
  • Know exact machine-level electricity costs: Measure kWh, kW, and Peak load per machine, per shift, and per line; identify costly idle running during off-hours.
  • Monitor Run / Stop / Idle & OEE: Track actual uptime, downtime causes, stamping cycle times, and shift output on clean, real-time dashboards.
  • 100% full ownership: Telemetry streams, as-built wiring diagrams, and gateway configs belong strictly to the factory with zero vendor lock-in.

NON-INVASIVE RETROFIT ACQUISITION ARCHITECTURE — ZERO PLC MODIFICATION

Existing Machines
Injection molding, Stamping, CNC, Compressors
➔
External Sensors
Split-core CT, Relay, Optical, PT100
➔
DeviceLab IoT Gateway
2.5kV Isolation · 30-Day Flash Buffer
➔
4G LTE / Dedicated LAN
Air-gapped from factory IT office network
➔
SCADA / MES / Cloud
Real-time Analytics Dashboard

Field Telemetry & Data Acquisition

5 Field Data Groups Captured by DeviceLab

Acquired directly via non-invasive clamp sensors and industrial meters, feeding clean telemetry straight to SCADA, MES, or Cloud.

01

Group 1: Machine Status & OEE (Legacy Retrofit)

Capture dry contact relays, auxiliary contactors, Andon tower lights, or external CT current sensors to accurately classify Run, Idle, and Stop states; measure operating uptime and stamping cycle time per shift.

02

Group 2: Sub-Metered Electrical Energy

Measure voltage (V), current (A), active power (kW), consumption (kWh), power factor cosφ, and harmonics across individual distribution boards and heavy machinery. Pinpoint after-hours idle energy waste.

03

Group 3: Piece Count & Specific Energy (kWh/Unit)

Install optical/proximity sensors or read pulse counters for real-time output quantification. Automatically compute kWh consumed per unit produced (kWh/unit) for precision manufacturing cost accounting.

04

Group 4: Temperature, Humidity & Equipment Health

PT100/NTC temperature probes on motor housings, air compressors, chillers, and VFDs; ambient humidity in warehouses and electrical cabinets. Early alert for thermal breakdown and component degradation.

05

Group 5: Auxiliary Utilities (Compressed Air & Cooling Water)

Pipeline pressure transmitters and cooling water flowmeters. Detect pressure drops and compressed air leaks immediately — one of the largest hidden overhead costs in manufacturing.

Safety Guarantee

Our 3 ZERO Commitments for Factory Deployments

Engineering execution prioritizes plant operational safety, eliminating all risks of production interruption.

ZERO Production Downtime

Utilize split-core CTs clamped externally over cables, independent sensors, and safe parallel connections during scheduled maintenance or shift changeovers.

ZERO PLC Program Alteration

Strictly no code changes, no logic overwrites, and no reprogramming of existing PLCs. Original factory automation logic remains 100% untouched.

ZERO IT Network Intrusion

IoT Gateways use dedicated industrial 4G LTE Cat-1 cellular uplinks to transmit data to Cloud or On-Premise servers, physically air-gapped from internal office LANs.

Common Factory Pain Points

Operational Obstacles When Operating Without Real-Time Telemetry

Most factories possess durable mechanical machines but lack granular, real-time figures required to cut operational costs.

01

Only a bulk electricity bill at month-end

Power expenses surge by thousands of dollars, but management cannot determine which line, shift, or idle machine caused the spike.

02

Legacy machines lack communication ports

Stamping presses, plastic injection molders, and chillers run reliably but lack digital communication to integrate into modern SCADA/MES.

03

Manual pen-and-paper shift logs

Workers record machine counts manually on clipboards. Data is delayed, error-prone, and cannot calculate accurate Overall Equipment Effectiveness (OEE).

04

Cheap commercial converters crash frequently

Off-the-shelf serial converters lack industrial isolation, crashing near heavy VFDs and losing telemetry permanently when connections drop.

DeviceLab Engineering Approach

External Retrofit Telemetry Layer — Safe, Robust & Non-Invasive

We bridge hardware, sensors, and field connectivity — the vital engineering link that pure software companies cannot handle.

Sub-metering down to individual cabinets & machines

Deploy multi-function Modbus RS485 power meters measuring V, A, kW, kWh, and cosφ per workshop, substation, and major equipment cluster.

Retrofit telemetry on legacy equipment

Extract run/stop/fault status, cycle times, and piece pulses via auxiliary contacts or external current clamps with zero PLC intervention.

Isolated gateway with local edge buffering

2.5kV optical isolation protects against electrical noise. Local Flash memory buffers data during outages, auto-resending with timestamp upon reconnect.

Seamless SCADA / MES / Cloud integration

Standardized MQTT/JSON, Modbus TCP, or RESTful API streams feed directly into client MES platforms, SCADA systems, or custom dashboards.

PoC Implementation Roadmap

5-Step PoC Roadmap: Real-World Testing Before Scaling

  1. 01

    01 — Target Machine Selection & KPI Definition

    Select 1–3 critical machines or 1 feeder line to capture (Run/Stop, kWh, output) and align on exact measurement metrics.

  2. 02

    02 — Field PoC Installation

    DeviceLab engineering team deploys gateways and clamp sensors on target units within 1–2 days with zero line shutdown.

  3. 03

    03 — 2–4 Weeks Continuous Telemetry

    System runs 24/7 logging real-time power consumption, operational states, machine cycle rhythms, and anomalous idle spikes.

  4. 04

    04 — ROI Analysis & Executive Report

    Formal report detailing idle waste hours, off-peak power losses, and quantified cost-saving opportunities with payback projections.

  5. 05

    05 — Confident Plant-Wide Scaling

    With proven precision and economic validation, management confidently rolls out the solution across all factory lines.

Deliverables & Intellectual Property Handover

  • Complete as-built electrical schematic and field device placement drawings
  • Comprehensive Register Map documentation for all meters and monitored equipment
  • Full gateway firmware, configurations, and API / MQTT connectivity documentation
  • Real-time visualization dashboard (<a href="https://demo.devicelab.vn/" target="_blank" rel="noopener noreferrer" style="color: #0284c7; font-weight: 700; text-decoration: underline;">view live demo</a>) or documented API endpoints for client IT/MES teams
  • Standard operating procedures, maintenance guides, and on-site technical training

Solution Fit Assessment

  • Manufacturing plants & FDI enterprises needing granular power accounting per shift and line
  • Factories with legacy mechanical, stamping, or molding machinery requiring digitization to SCADA/MES
  • Facilities subject to mandatory Scope 2 GHG inventories under Decision 42/2026/QD-TTg, ISO 50001, or CBAM export mandates
  • Management seeking a low-risk 1–3 machine proof-of-concept before allocating capital budgets
  • Projects seeking only to buy a few standalone energy meters without system integration
  • Requests requiring total reprogramming and overhaul of primary production line PLCs

FAQ

Factory Energy & Retrofit FAQs

Will installation cause any interruption to factory production?

Absolutely not. DeviceLab adheres strictly to our "3 ZERO" commitment: using split-core clamp CTs over existing power cables, non-invasive sensors, and executing connections during break intervals or scheduled maintenance.

Can old machines without digital communication ports be digitized?

Yes. We specialize in non-invasive IIoT retrofitting: tapping auxiliary run/stop relay contacts, Andon lights, proximity counters, or clamp-on current sensors to precisely determine running, idling, and downtime.

Does the system satisfy mandatory GHG inventory requirements under Decision 42/2026/QD-TTg?

Yes. The system provides an unbroken, auditable telemetry trail stored with timestamps, exporting monthly and annual Scope 2 emission reports that meet Vietnamese legal requirements (Decision 42/2026/QD-TTg) and ISO 50001 / ESG audits.

How is project pricing structured?

Pricing is modular, based on the number of metering points, machines monitored, sensor types required, and software ingestion endpoints. Following an on-site survey, DeviceLab provides a transparent turnkey quotation.

What happens if cellular 4G connectivity or local network drops?

No data is lost. DeviceLab industrial gateways feature local Flash buffering (Store-and-Forward). Telemetry is continuously recorded with timestamps and automatically synchronized once connectivity is restored.

Does the factory retain 100% ownership of data and engineering drawings?

Yes. 100% of telemetry data belongs strictly to the client and is hosted on client-designated servers or cloud accounts. As-built schematics, configs, and documentation are fully transferred upon handover.

Start with a practical 1–3 machine pilot

Have 1–3 legacy machines that need data acquisition, or need sub-metering for a specific workshop? Contact DeviceLab engineering team today for technical advice and an on-site evaluation.

✓ Mutual NDA before detailed exchange · ✓ Engineer response within 24 hours · ✓ Zero obligation